Array 3664A Programmable Bench Power Supply 0-120VDC 4.2A 500W

Number available: 1
£394.00
Array 3664 SMPS

The Array 366X series is a high efficiency 500W programmable switching power supply.
It features very low ripple and noise comparable with a traditional linear power supply.
It has a well designed control panel for quick and accurate adjustment as well as supporting SCPI remote control through serial RS232 interface.
It is a robust design for all laboratory requirements.

Features:
Provides CV and CC operating modes, switching automatically

The output voltage and output current are continuously adjustable from 0 to the maximum rating values

The maximum rating current can be achieved at 10mV. Equipped with SENSE terminals to compensate for the line loss

High power factor, high efficiency, wide line voltage range as well as low output ripple and noise

Multi-group setting parameters storage and recall
Robust, compact and convenient
SCPI (Standard Commands for Programmable Instruments) compatibility
Reliable input/output protections guarantee the effective operation in severe environment
  Specifications:
Model

3662A

3663A

3664A

Output Ratings

Voltage

0~35V

0~80V

0~120V

Current

0~14.5A

0~6.5A

0~4.2A

Ripple and Noise (20Hz to 20MHz)
Voltage
<3mVrms
<5mVrms
<8mVrms

<10mVpp

<14mVpp
<18mVpp
Current
<2mArms

500uArms

500uArms

Common Mode Current: 1.5mArms

Load Regulation (Voltage) <0.01%+2mV
Load Regulation (Current) <0.01%+1mA
Line Regulation (Voltage) <0.01%+2mV
Line Regulation (Current) <0.01%+1mA
Programming Accuracy
Voltage

0.1%+5mV

0.05%+20mV

0.05%+20mV

Current

0.2%+10mA

0.15%+4mA

0.15%+4mA

Readback Accuracy

Voltage

0.1%+5mV

0.05%+10mV

0.05%+10mV

Current

0.2%+10mA

0.15%+4mA

0.15%+4mA

Programming Resolution

Voltage

1mV

1mV

2mV

Current

1mA

1mA

1mA

Readback Resolution

Voltage

0.5mV

1mV

1mV

Current

1mA

1mA

1mA

Meter Resolution

Voltage

1mV

10mV

10mV

Current

1mA

1mA

1mA

Output Programming Range (maximum programmable values)

Voltage

0~35.2V
0~80.2V
0~120.2V
Current

0~14.5A

0~6.5A

0~4.2A

Temperature Coefficient, ±(% of output + offset)
Maximum change in output/readback per °C afer a 30-minute warm-up
Voltage
0.01% + 2 mV
0.01% + 3 mV
0.01% + 3 mV
Current

0.02% + 3 mA

0.02% + 0.5 mA

0.02% + 0.5 mA

Stability,±(% of output + offset)
Following a 30-minute warm-up,change in output over 8 hours under constant load,line and ambient temperature

Voltage

0.03% + 1 mV
0.02% + 2 mV
0.02% + 2 mV
Current

0.1% + 3 mA

0.05% + 1 mA

0.05% + 1 mA

Output Voltage Programming Response Time
Time for output to change from 10% to 90% of its total excursion(for resistive load).Command processing time is excluded
Full load up
11 msec
50 msec
50 msec
Full load down

13 msec

45 msec

45 msec

No load up
10 msec
20 msec
20 msec
No load down

10 msec

10 msec
10 msec

Power Supply AC100V-240V 47Hz~63Hz 750VA Max

Operating Temperature 0~40°C 0~80%RH

Cooling Fan Cooled

Output Voltage Overshoot Less than 1V
Programming Language SCPI(Standard Commands for Programmable Instruments)
Net Weight 5.5kg
Dimensions 212.6mm(W)×132.6mm(H)×360mm(D) (8.4×5.2×14.2 inch)

Full user manual is here: 366X User Manual